Do I Need the Battery Back Up for Uverse

How do I order a replacement FiberSafe™12 backup battery?

Why is my iPSU still showing a red flashing light after I replaced the FiberSafe battery with a new battery?

How can I tell if the iNID and the iPSU are working properly?

How long will it take to recharge a fully discharged FiberSafe12 backup battery?

How many years will the FiberSafe12 backup battery last?

How do I monitor the FiberSafe12 backup battery and what should I look for?

How many hours will the FiberSafe12 backup battery provide backup power?

Where is the Fibersafe12 backup battery located?

How do I replace my FiberSafe12 backup battery?

What should I do with my old FiberSafe12 backup battery?

Will my phones work with AT&T U-verse Voice service during a power outage?

What is the Warranty of the FiberSafe12 backup battery?

Am I responsible for monitoring the iPSU and maintaining and replacing the backup battery?

What kind of a battery is the FiberSafe12 backup battery and does it require any battery conditioning by me?

How does the FiberSafe12 battery backup system work?

What is the purpose of the FiberSafe12 backup battery?

What is the purpose of the iNID?

What is the purpose of the iNID Power Supply Unit (iPSU)?

How much does the FiberSafe12 backup battery weigh?

When a battery needs to be replaced, what information is required for warranty?

Do warmer and cooler temperatures affect the FiberSafe12 backup battery's service life or backup time?

How do I order a replacement FiberSafe™12 backup battery?
Call EnerSys Customer Service at 1-866-327-5755 between 8am – 5pm EST Monday through Friday. A credit card payment is required when placing a battery order via phone.

Why is my iPSU still showing a red flashing light after I replaced the FiberSafe battery with a new battery?

If you just replaced your battery and the power indicator light does not turn green within 5 minutes, check to ensure that the power supply is plugged in. Recheck your battery connections.

If battery is installed correctly, press reset button.

If light still does not light or you're still seeing a red flashing light and you've replaced the battery with a new battery, the problem is not the battery and you should call 1-800-288-2020 to be connected to AT&T Customer Service.

How can I tell if my iNID and the iPSU are working properly?

On the front of your iPSU there are two indicator lights. If your iPSU is receiving normal AC power, a solid green "Power" light on the left will be on. If the red "Battery" light on the right is flashing, this indicates that normal AC power is not working and the FiberSafe backup battery is providing DC power to the iNID or that the iNID is not yet communicating with the iPSU.

How long will it take to recharge a fully discharged FiberSafe12 backup battery?
The FiberSafe12 backup battery will recharge to 90% state of charge within 24 hours at 77°F (25°). However, it will take longer if the battery is colder.

How many years will the FiberSafe12 backup battery last?
The FiberSafe12 backup battery typically lasts 3-5 years at 77°F (25°C).

How do I monitor the FiberSafe12 backup battery and what should I look for?
You should monitor the lights (a green light means normal and a red flashing light means attention is required) and listen for any alarms coming from the iPSU. For a complete description of what all the lights and alarms mean view the iPSU Troubleshooting Guide.

How many hours will the FiberSafe12 backup battery provide backup power?
The fully charged Fibersafe12 backup battery will provide approximately 4 hours of battery backup time at 77°F (25°C).

Where is the Fibersafe12 backup battery located?

The FiberSafe12 backup battery is located inside the iNID Power Supply Unit (iPSU). The iPSU is typically located near where power comes into your home. The iPSU could be located in a sheltered area inside your home, such as an attached garage, a basement or a closet, and is plugged into a grounded wall outlet, preferably not on the floor.

How do I replace my FiberSafe12 backup battery?
Please refer to the Installation Instructions.

What should I do with my old FiberSafe12 backup battery?
Do not discard the FiberSafe12 backup battery in the trash. It is a sealed lead acid battery that must be properly recycled. We recommend that you take your used battery into your local recycling center or a national automotive battery supply store. Also, most retail stores that sell automotive lead acid batteries will accept small lead acid batteries for recycling. Other lead acid battery recycling centers can be located by calling the Portable Rechargeable Battery Association at 202-719-4978.

Will my phones work with AT&T U-verse Voice service during a power outage?
Your home's cordless phones will not function during a power outage without a separate battery backup, and not all cordless phones are so equipped.

It is recommended that you have one corded single-line touchtone phone directly connected to your home networking hub or your in-home wiring for use in the event of a power outage.

What is the Warranty of the FiberSafe12 backup battery?
FiberSafe12 batteries are warranted to be free of defects in materials and workmanship for a period of twelve (12) months from the latest date stamped/labeled on the battery cover.
See full warranty terms and conditions.

Am I responsible for monitoring the iPSU and maintaining and replacing the backup battery?
Yes. During installation of your AT&T U-verse Voice service, a new FiberSafe12 backup battery was installed. You are solely responsible for periodically monitoring the iPSU and promptly understanding and reacting to the warning lights and audible alarms. You are also responsible for replacing the battery when needed in order to maintain uninterruptable AT&T U-verse Voice service during a power outage.

What kind of a battery is the FiberSafe12 backup battery and does it require any battery conditioning by me?
The FiberSafe12 backup battery is a Valve Regulated Lead Acid (VRLA) sealed rechargeable battery. It is manufactured by EnerSys. It is a 12 Volt (V) 12 Ampere hour (Ah) battery with a unique harness to make installation and removal safe and easy for customers. The FiberSafe12 backup battery does not require any conditioning, water or maintenance; only monitoring of the iPSU indicators is required.

How does the FiberSafe12 battery backup system work?
The FiberSafe12 backup battery is designed for use with your AT&T iPSU and your AT&T U-verse Voice service. It is housed within your AT&T iPSU. By design, when normal AC power to your home is interrupted, the FiberSafe12 backup battery automatically provides battery backup power for your AT&T U-verse Voice service, including 911 dialing, for up to 4 hours.

What is the purpose of the FiberSafe12 backup battery?
The purpose of the FiberSafe12 backup battery is to help maintain your AT&T U-verse Voice SM service in the event of a short disruption to the commercial power at your home. Your AT&T U-verse Voice service includes a FiberSafe12 battery in the iNID Power Supply Unit ("iPSU").

What is the purpose of the iNID?
The iNID, which is installed on the outside of your home, provides data interfaces and network capabilities that help deliver AT&T U-verse services (Advanced Digital TV, High Speed Internet, and Digital Home Phone service) to your home.

What is the purpose of the iNID Power Supply Unit (iPSU)?
The iPSU houses the FiberSafe12 backup battery and provides battery backup power for your AT&T U-verse Voice service in the event of a short loss of AC power in your home.

How much does the FiberSafe12 backup battery weigh?
The FiberSafe12 backup battery weighs approximately 8.82 pounds (4 kilograms).

When a battery needs to be replaced, what information is required for warranty?

You will need the letters and/or numbers embossed on the top of the battery or printed on the sticker.

Do warmer and cooler temperatures affect the FiberSafe12 backup battery's service life or backup time?

Average Battery Temperature Capacity % / Backup Time Service Life
93°F (33°C) 100 % / 4 Hours 1.5-2.5 Years
77°F (25°C) 100 % / 4 Hours 3-5 Years
50°F (10°C) 90 % / 3.6 Hours 3-5 Years
32°F (0°C) 78 % / 3.1 Hours 3-5 Years
0°F (-17°C) 55 % / 2.2 Hours 3-5 Years

Do I Need the Battery Back Up for Uverse

Source: http://www.fibersafebattery.com/faq.aspx